{"product_id":"aten-tds-3593056-nrgence-pe6216a-16-outlets-pdu","title":"Aten PE6216A NRGence PE6216A 16-Outlets PDU","description":"\u003cp\u003eATEN NRGence PE6216A 16-Outlets PDU - IEC 60320 C20 - 14 x NEMA 5-15R, 2 x NEMA 5-20R - 120 V AC - 2400 W - Network (RJ-45) - Rack-mountable\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA 5-15R receptacle type to ensure maximum dependability and optimal performance\u003c\/li\u003e\n\u003cli\u003eIEC 60320 C20 plug\/connector type for reliable, productive connectivity and optimal power output\u003c\/li\u003e\n\u003cli\u003e120 V AC input voltage for optimal performance with maximum usability\u003c\/li\u003e\n\u003cli\u003e120 V AC output voltage for better reliance and maximum usability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eGeneral Information\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eATEN Technology, Inc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ePE6216A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer Website Address\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ehttp:\/\/www.aten.com\/us\/en\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eATEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Line\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eNRGence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Model\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ePE6216A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eNRGence PE6216A 16-Outlets PDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eMarketing Information\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eAs part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The NRGence PE6216 eco PDU is an intelligent PDU that contains 16 AC outlets and are available in various IEC or NEMA socket configurations.\u003cbr\u003e\u003cbr\u003e It provides secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ePDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eTechnical Information\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePlug\/Connector Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eIEC 60320 C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePlug\/Connector Detail\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e1 x IEC 60320 C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eNEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eNEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Detail\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e14 x NEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Detail\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e2 x NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003ePower Description\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePower Rating (Watt)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e2400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eManagement\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManagement\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\n\u003cul\u003e\u003cli\u003eeco PDU Power Management Software\u003c\/li\u003e\u003c\/ul\u003e\n\u003cb\u003eProtocols:\u003cbr\u003e\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eHTTP\u003c\/li\u003e\n\u003cli\u003eHTTPS\u003c\/li\u003e\n\u003cli\u003eSMTP\u003c\/li\u003e\n\u003cli\u003eDHCP\u003c\/li\u003e\n\u003cli\u003eNTP\u003c\/li\u003e\n\u003cli\u003eTCP\/IP\u003c\/li\u003e\n\u003cli\u003eUDP\u003c\/li\u003e\n\u003cli\u003eSSL\u003c\/li\u003e\n\u003cli\u003eSNMP v1, v2, v3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eInterfaces\/Ports\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eNetwork (RJ-45)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003ePhysical Characteristics\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eMount Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eRack-mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e1.7\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e52.2\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e2.6\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eWeight (Approximate)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e8.16 lb g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eMiscellaneous\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePackage Contents\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cul\u003e\n\u003cli\u003eNRGence PE6216A 16-Outlets PDU\u003c\/li\u003e\n\u003cli\u003e1x Power Cord\u003c\/li\u003e\n\u003cli\u003e1x Rack Mount Kit\u003c\/li\u003e\n\u003cli\u003e1x CD ROM (Manual, eco Sensors Software)\u003c\/li\u003e\n\u003cli\u003e1x User Instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eEnvironmentally Friendly\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eWaste Electrical and Electronic Equipment Directive (WEEE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eRestriction of Hazardous Substances (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Aten","offers":[{"title":"Default Title","offer_id":49005546340406,"sku":"PE6216A","price":684.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/1706\/6294\/files\/TDS_3593056.jpg?v=1795101725","url":"https:\/\/datasupplies.com\/products\/aten-tds-3593056-nrgence-pe6216a-16-outlets-pdu","provider":"Data Supplies","version":"1.0","type":"link"}