{"product_id":"eaton-mbp11k208g2-9px-g2-maintenance-bypass-for-select-8kva-to-11kva-9px-ups-systems-hardwired-input-output-4-l6-30r-outlets-0u-rack-tower-wall","title":"Eaton MBP11K208G2 9PX G2 Maintenance Bypass for Select 8kVA to 11kVA 9PX UPS Systems, Hardwired Input\/Output, 4 L6-30R Outlets, 0U Rack\/Tower\/Wall","description":"\u003cp\u003eEaton 9PX G2 Maintenance Bypass for Select 8kVA to 11kVA 9PX UPS Systems, Hardwired Input\/Output, 4 L6-30R Outlets, 0U Rack\/Tower\/Wall - 4 x NEMA L6-30R - 11 kW\/11 kW\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIsolates UPS from connected loads for maintenance without powering down equipment\u003c\/li\u003e\n\u003cli\u003eDesigned for 0U rear rack mounting, tower or wall mounting using the included hardware\u003c\/li\u003e\n\u003cli\u003eCompatible with Eaton's 8kVA to 11kVA 9PX G2 UPS systems\u003c\/li\u003e\n\u003cli\u003e3-year limited warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eGeneral Information\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eEaton Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eMBP11K208G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer Website Address\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ehttp:\/\/www.eaton.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Model\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eMBP11K208G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eMBP11K208G2 Bypass Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eMarketing Information\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures | Compatible with Select Eaton 8kVA\/11kVA 9PX G2 UPS Systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MBP11K208G2 works with Eaton's 9PX8KG2, 9PX8KTF5G2, 9PX11KG2, 9PX11KTF11G2 and 9PX11KTF5G2 UPS systems. The bypass switch lets you service or replace the UPS system without powering down any equipment and risking costly downtime. Power passes directly from a power source to equipment when in bypass mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Connection and Installation Options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MBP11K208G2 features hardwired input and output connections, as well as four NEMA L6-30R outlets. You can mount the maintenance bypass to the rear of the UPS or extended battery module (EBM) without taking up additional rack space. You can also mount the bypass on the side or top of the rack, on a wall or adapt it for tower installation using the included hardware.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eBypass Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eTechnical Information\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePlug\/Connector Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eHardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacles\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e4 x NEMA L6-30R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003ePower Description\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eLoad Capacity (VA)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eLoad Capacity (Watt)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e208 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e220 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003ePhysical Characteristics\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eRackmount\/Tower\/Wall-mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eRack Height\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e5.1\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e11.2\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e5.1\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eMiscellaneous\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePackage Contents\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cul\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cspan class=\"ql-ui\" contenteditable=\"false\"\u003e\u003c\/span\u003eMBP11K208G2 Bypass Switch\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cspan class=\"ql-ui\" contenteditable=\"false\"\u003e\u003c\/span\u003e2 x Input\/output Covers\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cspan class=\"ql-ui\" contenteditable=\"false\"\u003e\u003c\/span\u003eInput\/output Cover Fixation Kit\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cspan class=\"ql-ui\" contenteditable=\"false\"\u003e\u003c\/span\u003e2 x Conduits for UPS Input\/output Connection\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cspan class=\"ql-ui\" contenteditable=\"false\"\u003e\u003c\/span\u003e4 x Conduit Fittings\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cspan class=\"ql-ui\" contenteditable=\"false\"\u003e\u003c\/span\u003eMounting Hardware\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\n\u003cp\u003e\u003cstrong\u003eEaton 9PX G2 UPS Systems:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cspan class=\"ql-ui\" contenteditable=\"false\"\u003e\u003c\/span\u003e9PX8KG2\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cspan class=\"ql-ui\" contenteditable=\"false\"\u003e\u003c\/span\u003e9PX8KTF5G2\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cspan class=\"ql-ui\" contenteditable=\"false\"\u003e\u003c\/span\u003e9PX11KG2\u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cspan class=\"ql-ui\" contenteditable=\"false\"\u003e\u003c\/span\u003e9PX11KTF11G2 \u003c\/li\u003e\n\u003cli data-list=\"bullet\"\u003e\n\u003cspan class=\"ql-ui\" contenteditable=\"false\"\u003e\u003c\/span\u003e9PX11KTF5G2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ePhilippines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eRestriction of Hazardous Substances (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eWarranty\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eLimited Warranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e3 Year\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47582930108470,"sku":"MBP11K208G2","price":1349.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/1706\/6294\/files\/TDS_14642126.jpg?v=1788160106","url":"https:\/\/datasupplies.com\/products\/eaton-mbp11k208g2-9px-g2-maintenance-bypass-for-select-8kva-to-11kva-9px-ups-systems-hardwired-input-output-4-l6-30r-outlets-0u-rack-tower-wall","provider":"Data Supplies","version":"1.0","type":"link"}