{"product_id":"eaton-tds-3764150-metered-input-rack-pdu-5-76-kw-max-120-208v-16a-0u","title":"Eaton EMI318-10 Metered Input Rack PDU 5.76 kW max 120\/208V 16A 0U Three-Phase PDU","description":"\u003cp\u003eEaton Metered Input Rack PDU 5.76 kW max 120\/208V 16A 0U Three-Phase PDU - NEMA L21-20P - 30 x IEC 60320 C13, 6 x IEC 60320 C19, 3 x NEMA 5-20R - 120 V AC, 230 V AC - 5760 W - Network (RJ-45) - 38U - Rack-mountable\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNew ePDU G3 models feature \u0026amp;#177;1% billing grade accuracy, an advanced LCD pixel display, a hot-swap meter and the ability to daisy chain four ePDUs to share the same network connection and IP address\u003c\/li\u003e\n\u003cli\u003eHigh density units support up to 25 1U\/2U servers or three blade server chassis\u003c\/li\u003e\n\u003cli\u003eEasy read digital ammeter reduces local monitoring time\u003c\/li\u003e\n\u003cli\u003eClearly labeled circuits simplify load balancing\u003c\/li\u003e\n\u003cli\u003eReading available via Ethernet connection over a network\u003c\/li\u003e\n\u003cli\u003eUL Listed (UL489) branch circuit breakers meet UL60950-1 Edition requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eGeneral Information\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eEaton Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eEMI318-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer Website Address\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ehttp:\/\/www.eaton.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Line\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eePDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eePDU 39-Outlets PDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eMarketing Information\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eEaton G3 Metered Input ePDUs provide a best-in-class design featureing billing grade accuracy monitoring of input and branch circuits on a local LCD pixel display or over a network connection. The high accuracy meter will measure current, voltage, power and energy for load balancing, capacity planning, efficiency monitoring and energy usage reporting. Designed for IT and data center applications means high reliability and a robust design made for high operating temperatures found in containment or networking closets.\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eIEC outlet grip plug retention secures plugs in place using standard cables\u003c\/li\u003e\n\u003cli\u003eAdvanced LCD pixel display for local display of current, voltage, power, energy and menu setup of parameters such as IP address or display rotation\u003c\/li\u003e\n\u003cli\u003eHigh operating temperature (140F \/ 60C) for containment or hot network closet environments\u003c\/li\u003e\n\u003cli\u003eHot-swap meter for servicability of without removing power to the rack\u003c\/li\u003e\n\u003cli\u003e+\/- 1% billing grade accuracy for high accuracy reporting of energy usage\u003c\/li\u003e\n\u003cli\u003eDaisy chain of IP addresses allows four devices to share one network connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ePDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eTechnical Information\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePlug\/Connector Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eNEMA L21-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eIEC 60320 C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eIEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eNEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Detail\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e30 x IEC 60320 C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Detail\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e6 x IEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Detail\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e3 x NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003ePower Description\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e120 V AC - 208 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePower Rating (Watt)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e5760 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eInput Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eInterfaces\/Ports\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eNetwork (RJ-45)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003ePhysical Characteristics\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eMount Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eRack-mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eRack Height\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e38U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eCord Length\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e10 ft mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e66.5\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e2.1\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e2.1\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eWeight (Approximate)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e14.30 lb g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eMiscellaneous\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eWarranty\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eLimited Warranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e3 Year\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47582674649142,"sku":"EMI318-10","price":1134.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/1706\/6294\/files\/TDS_3764150.jpg?v=1788159629","url":"https:\/\/datasupplies.com\/products\/eaton-tds-3764150-metered-input-rack-pdu-5-76-kw-max-120-208v-16a-0u","provider":"Data Supplies","version":"1.0","type":"link"}