{"product_id":"mercop-8rp379","title":"APC by Schneider Electric APDU9953 Rack PDU 9000 Switched, ZeroU, 32A, 230V, (21) C13 \u0026 (3) C19","description":"\u003cp\u003eAPC by Schneider Electric Rack PDU 9000 Switched, ZeroU, 32A, 230V, (21) C13 \u0026amp; (3) C19 - Switched - IEC 60309 32A 2P+E - 21 x IEC 60320 C13, 3 x IEC 60320 C19 - 230 V AC - Overload Protection, Circuit Protection, Accidental Power Shutdown - Network (RJ-45) - 0U - Horizontal\/Vertical\/Toolless - Rack-mountable - Tower\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePDU distributes AC power to multiple servers and balances the load on the servers\u003c\/li\u003e\n\u003cli\u003eRemotely control individual outlets for rebooting of locked equipment with switched PDUs\u003c\/li\u003e\n\u003cli\u003eIEC 60320 C13 receptacle type to ensure maximum dependability and optimal performance\u003c\/li\u003e\n\u003cli\u003eIEC 60309 32A 2P+E plug\/connector type for efficient connectivity and feasible power output\u003c\/li\u003e\n\u003cli\u003e230 V AC input voltage for better reliance and maximum dependability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eGeneral Information\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eSchneider Electric SA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eAPDU9953\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer Website Address\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ehttp:\/\/www.schneider-electric.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Line\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eNetShelter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eSwitched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eRack PDU 9000 Switched, ZeroU, 32A, 230V, (21) C13 \u0026amp; (3) C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eMarketing Information\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\n\u003cp\u003e\u003cb\u003eWith Industry leading reliability, manageability, and security, APC Switched Rack PDU's provide advanced load management plus on\/off outlet level power cycling and sequencing control.\u003c\/b\u003e\u003c\/p\u003e \u003cp\u003eWith Industry leading reliability, manageability, and security, APC Switched Rack PDU's provide advanced load management plus on\/off outlet level power cycling and sequencing control.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ePDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eTechnical Information\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePDU Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eSwitched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePlug\/Connector Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eIEC 60309 32A 2P+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePlug\/Connector Detail\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e1 x IEC 60309 32A 2P+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eIEC 60320 C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eIEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Detail\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e21 x IEC 60320 C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eReceptacle Detail\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e3 x IEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProtection Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eOverload Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProtection Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProtection Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eAccidental Power Shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003ePower Description\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePower Rating (VA)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e7400 VA W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePower Rating (Watt)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e17.30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eInput Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eManagement\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManagement\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\u003cul\u003e \u003cli\u003eWeb\u003c\/li\u003e \u003cli\u003eSNMP\u003c\/li\u003e \u003cli\u003eTelnet\u003c\/li\u003e \u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eInterfaces\/Ports\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eNetwork (RJ-45)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003ePhysical Characteristics\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eHorizontal\/Vertical\/Toolless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eMount Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eRack-mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eRack Height\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e72\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e2.2\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e1.8\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eWeight (Approximate)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e16.18 lb g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eMiscellaneous\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePackage Contents\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\n\u003cli\u003eRack PDU 9000 Switched, ZeroU, 32A, 230V, (21) C13 \u0026amp; (3) C19 \u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003cli\u003eSafety guide\u003c\/li\u003e\n\u003cli\u003eSerial configuration cable\u003c\/li\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eWarranty\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eLimited Warranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e2 Year\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e","brand":"APC by Schneider Electric","offers":[{"title":"Default Title","offer_id":47009077559350,"sku":"APDU9953","price":2788.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/1706\/6294\/files\/8RP379_a119a0bb-cac1-4f5e-bf16-737593fd512c.jpg?v=1785579458","url":"https:\/\/datasupplies.com\/products\/mercop-8rp379","provider":"Data Supplies","version":"1.0","type":"link"}