{"product_id":"mercop-dm0154","title":"APC by Schneider Electric AP8841 APC NetShelter Metered Rack PDU, 0U, 5.0kW, 200V and 208V, 30A, 36 C13 and 6 C19 outlets","description":"\u003cp\u003eAPC NetShelter Metered Rack PDU, 0U, 5.0kW, 200V and 208V, 30A, 36 C13 and 6 C19 outlets - Metered - NEMA L6-30P - 200 V, 208 V - Overload Protection - 9.51 ft Cord Length - 0U - Vertical - Rack-mountable\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for colocation, large data centers or distributed IT sites\u003c\/li\u003e\n\u003cli\u003ePlan capacity and balance loads with +\/- 3% metering accuracy (amps, volts, kW, kWh)\u003c\/li\u003e\n\u003cli\u003eReal-time remote monitoring of connected load through EcoStruxureTM IT and other platforms\u003c\/li\u003e\n\u003cli\u003eStay on top by defining alarm thresholds in order to avoid overloaded circuits\u003c\/li\u003e\n\u003cli\u003e1-Year Secure Network Management Card subscription included\u003c\/li\u003e\n\u003cli\u003eInteractive LCD display\u003c\/li\u003e\n\u003cli\u003eActive power measurements (volts, amps, kW, kWh)\u003c\/li\u003e\n\u003cli\u003eEmbedded log memory\u003c\/li\u003e\n\u003cli\u003e9.84' power cord, 2-year APC warranty\u003c\/li\u003e\n\u003cli\u003eZero U toolless installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eGeneral Information\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eSchneider Electric SA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eAP8841\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManufacturer Website Address\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ehttp:\/\/www.schneider-electric.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eAPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Line\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eMetered Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Model\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eAP8841\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eMetered Rack AP8841 42-Outlets PDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eMarketing Information\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\n\u003cp\u003eThe APC Metered Rack PDU distributes reliable power within a rack through a single input and multiple output receptacles The AP8841 offers real-time remote monitoring of connected loads and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment The PDU can operate in a maximum ambient air temperature of up to 60°C (140°F) at full load The Network Management Card provides enhanced cybersecurity with secured interfaces and modified password policy The rack PDU integrates with EcoStruxure IT through a Network Management Card and can be accessed and configured via Web, SNMP, and Command Line Interface. User-interactive LCD interface details current, real power, voltage, and energy measurements for local user access. Embedded log memory with historical reporting enables users to meter power usage, optimize energy usage, and plan for capacity The PDU's locking IEC outlets, when used with locking power cords reduce the probability of accidentally disconnecting cords and dropping loads The rack PDU supports daisy-chaining of up to 4 PDUs on a single IP address An environmental monitoring port is available for external temperature\/humidity monitoring (sensor sold separately, model AP9335T or AP9335TH) The rack PDU comes with a standard two-year warranty Enables a quick recovery from overload events and breakers are ultra low profile. Packaging Includes PDU, Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable\u003c\/p\u003e \u003cp\u003e\u003ca id=\"gfk-spex-minisite\" rel=\"nofollow\" href=\"void(0)\"\u003eMore from the Manufacturer\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003ePDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eTechnical Information\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePDU Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eMetered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePlug\/Connector Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eNEMA L6-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eProtection Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eOverload Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003ePower Description\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e200 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e208 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eManagement\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eManagement\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\n\u003cp\u003e\u003cb\u003eProtocols:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSNMP\u003c\/li\u003e\n\u003cli\u003eTelnet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003ePhysical Characteristics\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eMount Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eRack-mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePlacement\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eSide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eRack Height\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eCord Length\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e9.51 ft mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e70.5\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e2.2\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e1.7\" mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eWeight (Approximate)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e15.08 lb g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eMiscellaneous\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003ePackage Contents\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e\n\u003cli\u003eMetered Rack AP8841 42-Outlets PDU \u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003cli\u003eSafety guide\u003c\/li\u003e\n\u003cli\u003eSerial configuration cable\u003c\/li\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eEnvironmentally Friendly\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eRestriction of Hazardous Substances (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eSingle-use Plastic (SUP) Free Shipping Packaging\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"margin:16px 0 6px;font-size:1.05em\"\u003eWarranty\u003c\/h4\u003e\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #e5e7eb;font-size:0.95em\"\u003e\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;width:40%;background:#f8f9fa;font-weight:600;vertical-align:top\"\u003eLimited Warranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border-bottom:1px solid #e5e7eb;vertical-align:top\"\u003e2 Year\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e","brand":"APC by Schneider Electric","offers":[{"title":"Default Title","offer_id":46655154454582,"sku":"AP8841","price":1434.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/1706\/6294\/files\/DM0154.jpg?v=1785579347","url":"https:\/\/datasupplies.com\/products\/mercop-dm0154","provider":"Data Supplies","version":"1.0","type":"link"}